<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Accessories &amp; Other &#8211; HITEC-INSTRUMENTS</title>
	<atom:link href="https://hitec-instruments.co.uk/product-category/accessories-other/feed/" rel="self" type="application/rss+xml" />
	<link>https://hitec-instruments.co.uk</link>
	<description>Equipment Shop WooCommerce WordPress Theme for Machine &#38; Tools</description>
	<lastBuildDate>Fri, 04 Sep 2026 06:25:26 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://hitec-instruments.co.uk/wp-content/uploads/2025/05/cropped-LOGO-Hitec_последнее-50x50.png</url>
	<title>Accessories &amp; Other &#8211; HITEC-INSTRUMENTS</title>
	<link>https://hitec-instruments.co.uk</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Satec Voltage Ratio Module for DC Metering Applications</title>
		<link>https://hitec-instruments.co.uk/product/voltage-ratio-module-dc-metering/</link>
		
		<dc:creator><![CDATA[Online Shopping]]></dc:creator>
		<pubDate>Wed, 27 May 2026 06:09:04 +0000</pubDate>
				<guid isPermaLink="false">https://hitec-instruments.co.uk/?post_type=product&#038;p=8495</guid>

					<description><![CDATA[The SATEC VRM Module is designed for connecting compatible SATEC meters to DC voltage systems above the direct voltage rating of the meter itself.]]></description>
										<content:encoded><![CDATA[<div>
<h6>The VRM module is used with DC metering systems up to 1500V DC</h6>
<div>• up to 600V DC for PM130 PLUS</div>
<div>• up to 800V DC for PRO EM235 and PM335 meters</div>
<p style="margin-top: 16px;"><strong>Compatible meters</strong></p>
<div>• SATEC PM130 PLUS</div>
<div>• SATEC PRO EM235</div>
<div>• SATEC PRO PM335</div>
</div>
<p style="margin-top: 16px;"><strong>Technical Characteristics</strong></p>
<div>• Accuracy: 0.1%</div>
<div>• 3 independent voltage inputs</div>
<div>• DIN-rail installation only</div>
<div>• Terminal wire size: 12 AWG (up to 3.5 mm²)</div>
<div>• Dimensions: 127 × 75 × 52 mm</div>
<div>
<div>• Weight: 80 grams</div>
</div>
<div></div>
<p style="margin-top: 16px;"><strong>The distance between the SATEC VRM module and the connected SATEC meter should not exceed 2 metres.</strong></p>
<div>Installation and electrical connection should be carried out by qualified personnel in accordance with local regulations.</div>
<div>Cabling with a minimum insulation rating of 600V should be used.</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>High Accuracy DC Current Sensors for Metering</title>
		<link>https://hitec-instruments.co.uk/product/high-accuracy-dc-current-sensors/</link>
		
		<dc:creator><![CDATA[Online Shopping]]></dc:creator>
		<pubDate>Fri, 22 May 2026 05:53:30 +0000</pubDate>
				<guid isPermaLink="false">https://hitec-instruments.co.uk/?post_type=product&#038;p=8443</guid>

					<description><![CDATA[<div>Some DC metering applications place high demands on measurement accuracy, bandwidth and installation constraints.</div>
<div>The DC metering range includes:</div>
<div>- Ultra High Accuracy Current Sensors (UHACS) with multi-point zero-flux technology and high-frequency ripple sensing.</div>
<div>- Hall Effect DC current sensors in solid core and split core formats for installations where conductors cannot easily be disconnected.</div>]]></description>
										<content:encoded><![CDATA[<p>Ultra High Accuracy Current Sensors (UHACS) are intended for DC metering applications requiring high measurement accuracy across the full bandwidth range. The UHACS range uses multi-point zero-flux technology together with a high-frequency ripple sensing channel.</p>
<div>Hall Effect DC current sensors are included for applications where installation conditions, conductor accessibility or retrofit requirements influence sensor selection. The DC metering range includes both solid core and split core formats across different current ratings.</div>
<h5>UHACS Sensors</h5>
<div>In high-accuracy DC metering, the current sensor is part of the measurement chain. Measurement stability, bandwidth response and ripple behaviour affect the quality of the recorded measurement data.</div>
<div>The FCS UHACS series uses solid core Ultra High Accuracy Current Sensors for metering applications where sensor performance matters as part of the system itself, not only the measured current value.</div>
<div>Multi-point zero-flux technology and a dedicated high-frequency ripple sensing channel sit at the centre of the UHACS design. The sensors are built for high gain and measurement accuracy across the full bandwidth range instead of simple nominal current indication alone.</div>
<div>UHACS models are specified with both DC and AC nominal current ratings, with AC values referenced as effective RMS values.</div>
<h6>The series includes:</h6>
<div>• FCS-300</div>
<div>• FCS-600</div>
<div>• FCS-1000</div>
<div>• FCS-2500</div>
<div>The UHACS series includes models from ±300A DC up to ±2500A DC.</div>
<h5>Hall Effect DC Current Sensors</h5>
<div>Hall Effect DC current sensors are used for DC current measurement in applications where installation access, retrofit conditions or conductor disconnection influence sensor selection.</div>
<div>The Hall Current Sensors includes both solid core and split core formats across different current ratings. Split core versions are used where an existing conductor cannot easily be disconnected during installation or replacement work.</div>
<div>The Hall Effect group includes:</div>
<div>• HCS100-S</div>
<div>• HCS1000</div>
<div>• HCS2000-S</div>
<div>The HCS models are intended for DC current measurement with compatible SATEC DC-metering devices.</div>
<div>Current ratings extend from 0–100A up to 2000A depending on sensor type and construction.</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HACS &#8211; High Accuracy Current Sensors</title>
		<link>https://hitec-instruments.co.uk/product/hacs-high-accuracy-current-sensors/</link>
		
		<dc:creator><![CDATA[Online Shopping]]></dc:creator>
		<pubDate>Tue, 19 May 2026 09:23:52 +0000</pubDate>
				<guid isPermaLink="false">https://hitec-instruments.co.uk/?post_type=product&#038;p=8404</guid>

					<description><![CDATA[Designed for selected SATEC meter models requiring high-accuracy current measurement with direct milliamp inputs.

Available in both solid-core and split-core versions, HACS sensors support new installations as well as retrofit projects where existing cabling cannot be disconnected.

<strong>Compatible SATEC meters are available with:</strong>
<ul>
 	<li>1A current inputs</li>
 	<li>5A current inputs</li>
 	<li>HACS milliamp current inputs</li>
</ul>
<strong>Compatible models include:</strong>
<ul>
 	<li>EM132/133 Series</li>
 	<li>PM130 PLUS Series</li>
 	<li>PM135</li>
 	<li>PM172 Series</li>
 	<li>PM174/175</li>
 	<li>BFM136</li>
 	<li>BFM II</li>
 	<li>PRO Series</li>
 	<li>PM180</li>
</ul>]]></description>
										<content:encoded><![CDATA[<div>HACS sensors are used in applications where accurate current measurement and installation flexibility are required across commercial, industrial, residential and utility environments.</div>
<div>The range supports both new-build and retrofit projects, including installations where the metering device must be installed remotely from the load or where existing conductors cannot be disconnected.</div>
<div>Unlike conventional 1A and 5A current transformer systems, HACS sensors operate directly with compatible SATEC meters using low-current milliamp inputs, reducing additional conversion stages within the metering chain.</div>
<div>The low-burden design supports installation distances of up to 200 m between the sensor and the meter without compromising measurement accuracy.</div>
<h5>Key functions</h5>
<ul>
<li>High Accuracy Measurement</li>
</ul>
<p>Conventional current transformer systems rely on additional current conversion stages between the transformer and the meter.<br />
HACS sensors are designed to operate directly with compatible SATEC meters using milliamp inputs for accurate current measurement.</p>
<ul>
<li>Split-Core and Solid-Core Versions</li>
</ul>
<p>The HACS range includes both solid-core and split-core versions for different installation requirements. Split-core models simplify retrofit installations where conductors cannot be disconnected.</p>
<ul>
<li>Electronic Safety Switch</li>
</ul>
<p>Selected HACS models include an integrated electronic safety switch, removing the need for external shorting blocks during installation and maintenance.</p>
<ul>
<li>Remote Installation</li>
</ul>
<p>HACS sensors support installation distances of up to 200 m between the sensor and the meter, providing additional flexibility where the meter cannot be mounted close to the load.</p>
<h5>Standards Compliance</h5>
<div>IEC 61869-1 Instrument transformers &#8211; Part 1: General requirements</div>
<div>IEC 61869-2 Instrument transformers &#8211; Part 2: Additional requirements for current transformers</div>
<h5>Installation Notes</h5>
<div>All HACS models are supplied with a 2.5 m cable.</div>
<div>Recommended cable extensions should use shielded twisted cable with the shield connected to protective ground.</div>
<div>For best installation practice, HACS cables should be routed separately from high-voltage circuits and strong magnetic fields.</div>