<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Power Meters &#8211; HITEC-INSTRUMENTS</title>
	<atom:link href="https://hitec-instruments.co.uk/product-category/power-meters/feed/" rel="self" type="application/rss+xml" />
	<link>https://hitec-instruments.co.uk</link>
	<description>Equipment Shop WooCommerce WordPress Theme for Machine &#38; Tools</description>
	<lastBuildDate>Thu, 19 Nov 2026 19:54:37 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://hitec-instruments.co.uk/wp-content/uploads/2025/05/cropped-LOGO-Hitec_последнее-50x50.png</url>
	<title>Power Meters &#8211; HITEC-INSTRUMENTS</title>
	<link>https://hitec-instruments.co.uk</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SATEC PM172 Class 0.2 Energy Meter</title>
		<link>https://hitec-instruments.co.uk/product/satec-pm172-energy-meter/</link>
		
		<dc:creator><![CDATA[Online Shopping]]></dc:creator>
		<pubDate>Sun, 22 Feb 2026 10:44:04 +0000</pubDate>
				<guid isPermaLink="false">https://hitec-instruments.co.uk/?post_type=product&#038;p=7551</guid>

					<description><![CDATA[High-accuracy energy metering for industrial and utility LV systems. Class 0.2 accuracy with revenue-grade capability, demand monitoring and harmonic analysis (EH), with Modbus, DNP3, Profibus and GE EGD support.

&#160;]]></description>
										<content:encoded><![CDATA[<h5>The SATEC PM172 Class 0.2 Energy Meter</h5>
<p data-start="822" data-end="1167">The PM172 is a panel-mounted energy meter for low-voltage distribution systems requiring accurate measurement and integration into existing control infrastructure. It provides electrical parameter monitoring and revenue-grade energy metering, with harmonic analysis available in the EH version, in a format suitable for switchboard installation.</p>
<p data-start="1169" data-end="1334">It is intended for continuous operation in industrial and utility environments, with communications options supporting integration into SCADA and automation systems.</p>
<p><a href="https://webstore.iec.ch/en/publication/29987?utm_source" target="_blank" rel="noopener">Accuracy in accordance with IEC 62053-22 (Class 0.2S)</a></p>
<h5 data-start="862" data-end="886">Measurement Capabilities</h5>
<p data-start="888" data-end="1245">The SATEC PM172 energy meter provides measurement of line-to-line and line-to-neutral voltages, phase and neutral currents, active, reactive and apparent power (per phase and total), power factor and system frequency. Voltage inputs are connected directly, with current measurement via external current transformers (CTs) according to the configured ratios.</p>
<h5 data-start="1247" data-end="1273">Energy and Demand (E / EH)</h5>
<p data-start="1275" data-end="1538">The PM172 supports import and export kWh and kvarh registers, present demand and configurable demand intervals based on user-defined integration periods. These functions enable revenue-grade submetering and internal energy allocation within industrial LV systems.</p>
<h5 data-start="1540" data-end="1562">Harmonic Analysis (EH)</h5>
<p data-start="1564" data-end="1803">The PM172EH version provides individual harmonic components up to the 50th order, Total Harmonic Distortion (THD) and waveform capture. Harmonic values are available per phase for distortion assessment in low-voltage distribution networks.</p>
<h5 data-start="0" data-end="23">Accuracy and Compliance</h5>
<p data-start="25" data-end="120">The PM172 exceeds ANSI C12.20 Class 0.2 requirements and complies with IEC 62053-22 Class 0.2S.</p>
<p data-start="122" data-end="247">Scaling is configurable via CT and PT ratios, allowing the meter to be applied across a wide range of primary system ratings.</p>
<p data-start="249" data-end="308">Real-time measurements are updated at one-second intervals.</p>
<p data-start="310" data-end="435" data-is-last-node="" data-is-only-node="">The declared accuracy makes the instrument suitable for revenue-grade submetering in industrial and commercial installations.</p>
<h5>Communications and Integration</h5>
<p data-start="1339" data-end="1369">Communications and Integration</p>
<p data-start="1371" data-end="1488">The SATEC PM172 supports serial and industrial communication protocols for integration into existing control systems.</p>
<h6>Serial Protocols</h6>
<ul>
<li>Modbus RTU</li>
<li>ASCII protocol</li>
<li>PML-DTE</li>
<li>RS-232 and RS-485 interfaces</li>
</ul>
<h6>Utility and Automation Protocols</h6>
<ul>
<li>DNP3</li>
<li>Profibus-DP</li>
<li>GE EGD (producer mode, UDP port 18246)</li>
</ul>
<p data-start="1677" data-end="1808">Communication uses defined register maps and structured data formats for integration into PLC, SCADA and energy management systems.</p>
<h5>Data Logging and Event Recording</h5>
<p data-start="1844" data-end="1923">The PM172 provides event logs, data logs and, in the EH version, waveform logs.</p>
<p data-start="1925" data-end="2024">Time synchronisation is supported for alignment with supervisory systems and plant time references.</p>
<h6>External Current Transformer Options</h6>
<p data-start="844" data-end="941">The PM172 is available in external CT configurations including PM17x-HACS and PM17x-RS5 variants.</p>
<p data-start="943" data-end="1131">The PM17x-HACS version supports high accuracy external current sensors rated up to 1200A. The PM17x-RS5 version is designed for 5A secondary current transformers (nominal 5A, maximum 10A).</p>
<p data-start="1133" data-end="1215">CT ratings from 100A to 1200A are available depending on the selected sensor type.</p>
<p data-start="1217" data-end="1427">CT primary current must be configured within the device setup. For HACS split-core models, transformer correction parameters (ratio and phase angle) are entered according to the values provided with the sensor.</p>
<p data-start="1429" data-end="1519">Only CTs supplied by SATEC may be used in order to maintain declared measurement accuracy.</p>
<h6>Remote Options</h6>
<p data-start="1171" data-end="1283">For installations requiring remote display or distributed measurement, the PM172 supports the following options:</p>
<ul>
<li>RPM072 remote power meter (transducer version)</li>
<li>RDM172 remote display module via RS-485</li>
</ul>
<p data-start="1377" data-end="1496">These options allow separation of measurement and display functions where panel layout or space constraints require it.</p>
<h6>Mechanical and Installation</h6>
<p>The PM172 is designed for panel mounting using either an ANSI 4-inch round cut-out or a DIN 92 × 92 mm square cut-out. The PM172 can also be mounted on a 35 mm DIN rail, with the display fitted separately and connected via the communication cable.</p>
<h6>Typical Applications</h6>
<ul>
<li>Industrial LV distribution boards</li>
<li>Commercial sub-metering and tenant energy allocation</li>
<li>Utility feeder monitoring</li>
<li>Integration into SCADA and energy management systems</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SATEC EM132 Multifunction Power Meter and Smart Transducer</title>
		<link>https://hitec-instruments.co.uk/product/satec-em132-power-meter/</link>
		
		<dc:creator><![CDATA[Online Shopping]]></dc:creator>
		<pubDate>Fri, 20 Feb 2026 13:45:16 +0000</pubDate>
				<guid isPermaLink="false">https://hitec-instruments.co.uk/?post_type=product&#038;p=7491</guid>

					<description><![CDATA[<p data-start="0" data-end="196">Designed for switchboards and motor control centres, this unit provides dependable three-phase energy measurement where stable kWh and demand data matter more than advanced power quality analysis.</p>
<p data-start="198" data-end="497" data-is-last-node="" data-is-only-node="">It supports direct connection up to 63 A or 1 A / 5 A CT inputs, includes RS-485 Modbus as standard, and offers modular communication and I/O expansion options. A practical choice for structured sub-metering, panel upgrades and retrofit projects where space, clarity and integration discipline are critical.</p>]]></description>
										<content:encoded><![CDATA[<h4>SATEC EM132 multifunction power meter – LV distribution specification</h4>
<h5 data-start="1000" data-end="1047">Measurement functions and recorded values</h5>
<p data-start="441" data-end="774">The SATEC EM132 multifunction power meter is used in LV switchboards where repeatable kWh, demand and load data are required for feeder monitoring, energy reporting and routine operational checks. It provides true RMS electrical measurement and logging for standard panel applications and is not intended as a power quality analyser.</p>
<p data-start="776" data-end="979">The EM132 measures voltage, current, active power (kW), reactive power (kvar), apparent power (kVA), power factor, frequency, energy (import and export), demand and load values in three-phase LV systems.</p>
<p><a href="https://hitec-instruments.co.uk/wp-content/uploads/2026/02/em132-datasheet.pdf" target="_blank" rel="noopener">SATEC <span class="a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none">EM132 Datasheet</span></a></p>
<h5>Electrical inputs</h5>
<p data-start="1604" data-end="1702">Voltage inputs: direct measurement 0–690 V AC.<br data-start="1658" data-end="1661" />Frequency range: 25–400 Hz.</p>
<h5 data-start="1704" data-end="1757">Current input options (application dependent):</h5>
<ul>
<li data-start="1760" data-end="1788">63 A direct connection</li>
<li data-start="1791" data-end="1826">1 A / 5 A CT secondary inputs</li>
<li data-start="1829" data-end="1890">40 mA input for SATEC HACS CTs (100–3000 A)</li>
<li data-start="1893" data-end="1963">RS input for 5 A rated split-core HACS CTs</li>
</ul>
<h5 data-start="1965" data-end="1994">Accuracy and compliance</h5>
<p>Active energy accuracy complies with <a href="https://webstore.iec.ch/en/publication/29987?utm_source" target="_blank" rel="noopener">IEC 62053-22 Class 0.5S</a>.</p>
<p>EMC and immunity compliance is in accordance with IEC 60688 and IEC 62052-11, including test coverage under IEC 61000-4-2, -3, -4, -5, -6 and -8.</p>
<p>Safety compliance includes UL/<a href="https://webstore.iec.ch/en/publication/4279?utm_source" target="_blank" rel="noopener">IEC 61010-1</a> and UL 916.</p>
<h5 data-start="2319" data-end="2345">Power supply options</h5>
<p>Auxiliary supply (standard range): 57.7–277 V AC and 48–290 V DC.<br data-start="1710" data-end="1713" />Optional supply: 12–24 V DC (±20%).</p>
<h5 data-start="2517" data-end="2553">Built-in communications (COM1)</h5>
<p data-start="2554" data-end="2756">The EM132 is supplied with an RS-485 communication interface as standard. Maximum baud rate is 115.2 kb/s, with cable length up to 1000 m, optically isolated.</p>
<h5 data-start="2758" data-end="2784"><strong data-start="2758" data-end="2782">Protocols on RS-485:</strong></h5>
<ul>
<li data-start="2787" data-end="2811">Modbus RTU / ASCII</li>
<li data-start="2814" data-end="2826">DNP3.0</li>
<li data-start="2829" data-end="2857">IEC 60870-5-101 (option)</li>
</ul>
<h5 data-start="2063" data-end="2098">Plug-in communication modules</h5>
<p>Plug-in modules extend the communication interface where required by the project specification.</p>
<p>Ethernet (10/100Base-T, RJ45): supports Modbus/TCP (502), IEC 60870-5-104 and DNP3/TCP (20000), with up to four simultaneous connections (two Modbus/TCP and two DNP3/TCP).</p>
<p>Cellular module: supports Modbus/TCP (502) and DNP3/TCP (20000).</p>
<p>PROFIBUS-DP (IEC 61158): optically isolated RS-485 interface, 9.6 kb/s to 12 Mbit/s (auto-detection), 32 bytes input / 32 bytes output.</p>
<p>RS-232 / RS-422/485 module: optically isolated, up to 115.2 kb/s.</p>
<h5 data-start="259" data-end="286">Digital and analogue I/O</h5>
<p data-start="288" data-end="372">Built-in I/O<br data-start="304" data-end="307" />Two digital inputs and one Form A solid-state relay (SSR) output.</p>
<h6 data-start="374" data-end="406"><strong data-start="374" data-end="406">Optional plug-in I/O modules</strong></h6>
<p data-start="2823" data-end="2990">4DIO module<br data-start="2838" data-end="2841" />Four digital inputs and two relay outputs (SSR or electromechanical relay). One-cycle update. Output modes include unlatched, latched, pulse and KYZ.</p>
<p data-start="2992" data-end="3116">12DIO module<br data-start="3008" data-end="3011" />Twelve digital inputs and four relay outputs. Optional communication port: Ethernet or additional RS-485.</p>
<p data-start="3118" data-end="3281">4AO module<br data-start="3132" data-end="3135" />Four analogue outputs with internal supply. Selectable output ranges: 0–20 mA, 4–20 mA, 0–1 mA, 0–3 mA, 0–5 mA, ±1 mA and ±5 mA. One-cycle update.</p>
<p data-start="3283" data-end="3341">8DI module<br data-start="3297" data-end="3300" />Eight digital inputs with 1 ms scan time.</p>
<p data-start="3343" data-end="3460">2AI module<br data-start="3357" data-end="3360" />Two analogue inputs, 4–20 mA. Availability dependent on the specified cellular module configuration.</p>
<h5>Model variants</h5>
<p data-start="3489" data-end="3758">EM132 – standard model<br data-start="3515" data-end="3518" />DIN-rail multifunction power meter with direct connection up to 63 A or 1 A / 5 A CT inputs. Built-in RS-485 supporting Modbus RTU/ASCII and DNP3.0 (IEC 60870-5-101 optional). Compatible with plug-in communication and I/O expansion modules.</p>
<p data-start="3760" data-end="3897">EM132-TP – additional built-in RS-485<br data-start="3801" data-end="3804" />Includes a second built-in RS-485 port. Available only with the auxiliary power supply model.</p>
<h5 data-start="5011" data-end="5042">Typical applications (LV)</h5>
<p data-start="3937" data-end="3996">The SATEC EM132 multifunction power meter is specified for:</p>
<ul>
<li data-start="4000" data-end="4041">LV distribution boards and switchboards</li>
<li data-start="4044" data-end="4065">MCC feeder metering</li>
<li data-start="4068" data-end="4117">Structured tenant and departmental sub-metering</li>
<li data-start="4120" data-end="4166">Retrofit panels using CT/HACS configurations</li>
<li data-start="4169" data-end="4237">SCADA and BMS integration where protocol selection is site-defined</li>
</ul>
<p data-start="4239" data-end="4349">It is selected where dependable three-phase energy measurement and structured system integration are required.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SATEC PM130 PLUS Multifunction Power Meter</title>
		<link>https://hitec-instruments.co.uk/product/pm130-plus-power-meter/</link>
		
		<dc:creator><![CDATA[Online Shopping]]></dc:creator>
		<pubDate>Tue, 17 Feb 2026 16:13:45 +0000</pubDate>
				<guid isPermaLink="false">https://hitec-instruments.co.uk/?post_type=product&#038;p=7451</guid>

					<description><![CDATA[The PM130 PLUS is built for LV/MV switchboards and metering panels, with DIN-rail or panel mounting options and modular communications/I/O for consistent system integration. It provides stable kWh and demand data via RS-485 (Modbus RTU), with optional communications and I/O expansion to match project requirements.]]></description>
										<content:encoded><![CDATA[<h5>SATEC PM130 PLUS multifunction power meter is a three-phase power meter for industrial and utility energy metering, designed for reliable integration into monitoring and control systems.</h5>
<p data-start="68" data-end="355">The PM130 PLUS measures voltage, current, power, energy and frequency, with support for multiple communication protocols and plug-in I/O expansion modules. All models share the same communication and control platform, which keeps integration consistent across projects and panel designs.</p>
<p data-start="357" data-end="593">The PM130 PLUS is commonly specified for switchboards, motor control centres (MCCs) and metering panels where stable kWh data, demand values and clear system visibility are required without the overhead of a full power quality analyser.</p>
<h5 data-start="595" data-end="730">Models</h5>
<p data-start="595" data-end="730">PM130P PLUS – Power meter<br data-start="637" data-end="640" />PM130E PLUS – Energy meter<br data-start="670" data-end="673" />PM130EH PLUS – Energy meter with harmonic measurement</p>
<p style="margin-top: 10px;"><a href="https://hitec-instruments.co.uk/wp-content/uploads/2026/02/pm135-datasheet.pdf" target="_blank" rel="noopener">SATEC </a><a href="https://hitec-instruments.co.uk/wp-content/uploads/2026/02/pm130-plus-datasheet.pdf" target="_blank" rel="noopener">PM130 PLUS Datasheet</a></p>
<h5>Key functions</h5>
<ul>
<li>Three-phase AC energy metering for industrial and utility applications</li>
<li>Measurement of voltage, current, active, reactive and apparent power</li>
<li>Active, reactive and apparent energy (kWh, kvarh, kVAh)</li>
<li>Demand measurement and load profiling</li>
<li>Class 0.5 / 0.5S accuracy (<a href="https://webstore.iec.ch/en/publication/29987?utm_source" target="_blank" rel="noopener">IEC 62053-22</a>, model dependent)</li>
<li>Harmonic measurement capability (PM130EH)</li>
<li>Built-in RS-485 communication (Modbus RTU)</li>
<li>Optional communication modules: Ethernet, PROFIBUS DP, DNP3, IEC 60870-5-101/104</li>
<li>Modular I/O expansion: digital inputs, relay outputs and analogue outputs</li>
<li>Local display and keypad for configuration, diagnostics and commissioning</li>
</ul>
<h5>Measurement inputs and I/O</h5>
<p data-start="346" data-end="703">The SATEC PM130 PLUS is built for three-phase metering in LV and MV panels, using external current transformers (CTs) sized to the feeder or circuit. It measures phase-to-phase and phase-to-neutral voltages, line currents, active/reactive/apparent power, energy (kWh, kvarh, kVAh) and frequency, and remains stable on both balanced and unbalanced loads.</p>
<p data-start="705" data-end="1031">The PM130 PLUS uses a modular I/O concept. Depending on the build, you can add plug-in communication and I/O modules such as digital inputs, relay outputs and analogue outputs. This makes it straightforward to bring status signals, alarms and control points into the same meter used for energy and electrical measurements.</p>
<h5>External meter pulse inputs</h5>
<p data-start="346" data-end="703">The PM130E PLUS can receive pulses from external electricity, gas and water meters through its optional digital inputs. With the TOD (TOU+4DI) module fitted, four digital inputs are available for this purpose.</p>
<p data-start="705" data-end="1031">The inputs can be linked to pulse counters or programmable energy/TOU registers. The resulting values can be read by a building management system (BMS) through the meter&#8217;s standard RS-485 interface using Modbus RTU.</p>
<h5 data-start="93" data-end="143">Digital event logging and waveform capture</h5>
<p data-start="407" data-end="668">The PM130 PLUS provides event logging for operational and diagnostic purposes, recording time-stamped alarms, setpoint activity and selected status changes. This allows engineers to review system behaviour during commissioning and basic fault investigation.</p>
<p data-start="670" data-end="929">Depending on the model and configuration, the meter also supports waveform capture associated with selected events. This provides additional visibility into voltage and current behaviour where required, without the need for a dedicated power quality analyser.</p>
<h5>Communication &amp; I/O</h5>
<p data-start="389" data-end="722">The SATEC PM130 PLUS multifunction power meter includes an RS-485 interface with Modbus RTU for integration with PLC and SCADA systems. Additional protocols are available via plug-in communication modules, including Ethernet, PROFIBUS DP, DNP3 and IEC 60870-5-101/104, which supports utility and industrial interoperability requirements.</p>
<p data-start="724" data-end="1068">I/O is expanded using dedicated plug-in modules. Depending on configuration, the meter can be fitted with digital inputs for status monitoring, relay outputs for alarms or simple control, and analogue outputs for legacy interfaces. The modular approach lets you specify only the communications and I/O you need, without changing the base meter.</p>
<h5>Applications</h5>
<p data-start="287" data-end="576">The PM130 PLUS is used for industrial and utility metering where stable electrical and energy data is needed for monitoring, reporting and basic control. It is commonly installed in LV and MV switchboards for incomer and feeder metering, sub-metering and panel-level energy monitoring.</p>
<p data-start="578" data-end="988">Typical use cases include industrial plants, commercial sites and infrastructure projects, as well as utility installations where the meter is integrated into PLC or SCADA systems to provide measured values, energy totals and demand data. It is also a practical choice for retrofit work, where modular communications and I/O help bring existing panels into a modern monitoring platform with minimal disruption.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SATEC PM135 Multifunction Power Meter 3-Phase</title>
		<link>https://hitec-instruments.co.uk/product/pm135-multifunction-power-meter/</link>
		
		<dc:creator><![CDATA[Online Shopping]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 06:56:51 +0000</pubDate>
				<guid isPermaLink="false">https://hitec-instruments.co.uk/?post_type=product&#038;p=7269</guid>

					<description><![CDATA[The SATEC PM135 is a compact range of multifunction three-phase power meters for LV and MV applications. It measures voltage, current, active, reactive and apparent power, power factor and frequency, with model-dependent energy and TOU metering, data recording and harmonic analysis.

Standard RS-485 and a choice of one optional plug-in module for communications or I/O support straightforward integration with industrial control, monitoring and SCADA systems. The range is suitable for panel builders, industrial facilities, utilities and energy-monitoring projects requiring dependable electrical data and flexible system integration.]]></description>
										<content:encoded><![CDATA[<h4>SATEC PM135 multifunction power meter</h4>
<p class="isSelectedEnd">The SATEC PM135 is a compact range of multifunction three-phase power meters designed for reliable electrical measurement and straightforward integration into industrial and utility control and monitoring systems. The range measures voltage, current, active, reactive and apparent power, power factor and frequency, with RS-485 (EIA-485) as standard and optional communication interfaces for integration with PLC and SCADA systems.</p>
<p class="isSelectedEnd">The PM135 is commonly specified for plant switchboards, MCCs and utility metering panels. Energy and TOU metering, power demand and data recording are provided by the PM135E and PM135EH.</p>
<p>The range covers straightforward three-phase power and energy metering, with harmonic analysis available in the PM135EH, for applications where the functions of a full power quality analyser are not required.</p>
<h5>Models</h5>
<ul>
<li>PM135P – Power Meter</li>
<li>PM135E – Energy Meter</li>
<li>PM135EH – Energy Meter with Harmonic Measurement</li>
</ul>
<p style="margin-top: 10px;"><a href="https://hitec-instruments.co.uk/wp-content/uploads/2026/02/pm135-datasheet.pdf" target="_blank" rel="noopener">SATEC </a><a href="https://hitec-instruments.co.uk/wp-content/uploads/2026/02/pm135-datasheet.pdf" target="_blank" rel="noopener">PM135 Datasheet</a></p>
<h5>Key functions</h5>
<ul>
<li>True RMS voltage and current measurement, with active, reactive and apparent power, power factor, frequency, neutral current, phase angles and voltage and current unbalance</li>
<li>Energy and TOU metering (PM135E and PM135EH), including four-quadrant active and reactive energy and total and per-phase active, reactive and apparent energy</li>
<li>Class 0.5S active-energy accuracy to <a href="https://webstore.iec.ch/en/publication/29987?utm_source" target="_blank" rel="noopener">IEC 62053-22</a> (PM135E and PM135EH)</li>
<li>Voltage and current demand across the range, with power demand, periodic data logging and automatic daily energy and maximum-demand profile logging on the PM135E and PM135EH</li>
<li>Harmonic analysis (PM135EH), including voltage and current harmonic spectra and angles up to the 40th order, voltage and current THD, current TDD and K-factor</li>
<li>Standard RS-485 communication, with an optional Ethernet port, PROFIBUS DP port or additional RS-232/RS-422/RS-485 serial port; supported protocols depend on the communication option fitted</li>
<li>One optional plug-in expansion module, providing digital inputs, relay outputs, analogue outputs or additional communications, depending on the selected configuration</li>
<li>Embedded programmable controller with 16 setpoints, programmable thresholds and delays, and one-cycle response time; control actions can be assigned to optional relay outputs</li>
<li>Local HMI with display and keypad for commissioning checks and on-site diagnostics</li>
</ul>
<h5>Measurement inputs and I/O</h5>
<p class="isSelectedEnd">The SATEC PM135 range is designed for three-phase measurement in LV and MV panels. It supports direct voltage measurement up to 690 V AC line-to-line or measurement through external voltage transformers for MV applications, together with 1 A or 5 A CT secondary inputs and optional SATEC HACS current sensors.</p>
<p class="isSelectedEnd">Depending on the wiring configuration, the range measures line-to-line and, where applicable, line-to-neutral voltages, line currents, active, reactive and apparent power, power factor, frequency, neutral current and voltage and current unbalance. Energy measurements are available in the PM135E and PM135EH.</p>
<p>One optional plug-in expansion module can be fitted to each meter. Depending on the selected configuration, this may provide digital inputs, relay outputs, analogue outputs or an additional communication interface for status monitoring, alarms and control within industrial systems.</p>
<h5 data-start="93" data-end="143">Event and data logging and real-time waveform monitoring</h5>
<p class="isSelectedEnd">The PM135E and PM135EH provide non-volatile event and data recording. The event recorder stores time-stamped configuration changes, resets and internal diagnostic events. Two data recorders can log selected measurements at configurable intervals and support automatic daily energy and maximum-demand profile logging.</p>
<p class="isSelectedEnd">Waveform functionality is separate from the event and data logs. Real-time scope-mode monitoring through PAS software provides a live view of voltage and current waveforms for commissioning and diagnostic work.</p>
<p>Together, the stored records and live waveform view support commissioning and diagnostics. They do not replace a dedicated power quality analyser or protection device.</p>
<h5>Communication &amp; I/O</h5>
<p class="isSelectedEnd">The PM135 range integrates with PLC and SCADA systems through a standard optically isolated RS-485 port and optional communication interfaces. Depending on the communication option ordered, supported protocols can include Modbus RTU, DNP3, SATEC ASCII and IEC 60870-5-101 on serial interfaces, and Modbus TCP, DNP3/TCP and IEC 60870-5-104 over optional Ethernet. PROFIBUS DP and an additional RS-232/RS-422/RS-485 interface are also available as plug-in options.</p>
<p>A single plug-in expansion module can be fitted to each meter. The functions available depend on the selected module and may include digital inputs, relay outputs, analogue outputs or an additional communication interface.</p>
<h5>Applications</h5>
<p class="isSelectedEnd">The PM135 range is used where dependable three-phase electrical measurement and communications are required. Typical applications include industrial monitoring and sub-metering in manufacturing plants, process facilities and commercial buildings, as well as metering in MCCs, switchboards and distribution panels.</p>
<p>In utility and infrastructure projects, PM135 meters can be integrated into LV and MV monitoring schemes using protocols including Modbus RTU, IEC 60870-5-101/104, DNP3 and PROFIBUS DP. Applications also include energy monitoring and cost allocation in data centres, hospitals and multi-tenant facilities.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SATEC EM133</title>
		<link>https://hitec-instruments.co.uk/product/satec-em133/</link>
		
		<dc:creator><![CDATA[Maksym Sokolyk]]></dc:creator>
		<pubDate>Fri, 21 Nov 2025 16:39:42 +0000</pubDate>
				<guid isPermaLink="false">https://hitec-instruments.co.uk/?post_type=product&#038;p=6426</guid>

					<description><![CDATA[SATEC EM133 is a multifunction power meter, ideal for a wide range of applications such as revenue metering, industrial power monitoring and for interfacing SCADA in utility substations.

The EM133 can be fitted with a wide range of communication interfaces and I/O extensions, making it a cost-effective combination of a power meter, smart transducer and PLC controller.

MID certified for revenue metering, it is designed for DIN-rail mounting, equipped with built-in communication ports, digital I/Os and anti-tamper enclosures.]]></description>
										<content:encoded><![CDATA[<p>SATEC EM133 is Smart TOU Energy Meter and Transducer, ideal for a wide range of applications such as revenue metering, industrial power monitoring and for interfacing SCADA in utility substations.</p>
<p>Based the SATEC PM13X family functionality, it is a version designed as DIN-rail mount, equipped with built-in communication ports, digital I/Os and antitamper enclosures.</p>
<p>The EM133 provides the full functionality of the PM130EH PLUS combined with 2 Digital Inputs, 1 Digital Output, IR (Infra Red) communication and battery backup for the real time clock. It is fully compatible with all PM130 PLUS modules.</p>
<h4>Energy Meter Accuracy</h4>
<ul>
<li>Class 0.5S IEC 62053-22</li>
</ul>
<h4>Revenue Meter</h4>
<ul>
<li><strong>MID certified</strong></li>
<li>IR (Infra Red) interface</li>
<li>Anti-tamper design</li>
<li>Can bill 3 individual single phase clients</li>
</ul>
<h4>Communication &amp; I/O</h4>
<ul>
<li>Built-in port: RS485, IR (optical)</li>
<li>Optional ports: Ethernet, Wi-Fi, 3G/4G cellular, PROFIBUS</li>
<li>Protocols: Modbus, DNP3, IEC 60870-5-101/104</li>
<li>Built-in I/O: 1 RO, 2 DI</li>
<li>Modular I/O: up to 16 I/O</li>
</ul>
<h4>Broad-range measurement</h4>
<ul>
<li>Voltage: 15-828V AC (direct, L-L)</li>
<li>Frequency: 25, 50, 60, 400 Hz</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SATEC PM335 PRO</title>
		<link>https://hitec-instruments.co.uk/product/satec-pm335-pro/</link>
		
		<dc:creator><![CDATA[Maksym Sokolyk]]></dc:creator>
		<pubDate>Tue, 18 Nov 2025 19:25:22 +0000</pubDate>
				<guid isPermaLink="false">https://hitec-instruments.co.uk/?post_type=product&#038;p=6031</guid>

					<description><![CDATA[SATEC PM335 PRO is a cost-effective power meter specifically designed for advanced power monitoring applications involving both AC and DC currents.
Equipped with waveform recording capabilities and 16GB storage capacity, it serves as a robust Class A, Ed. 3 power-quality analyzer and event recorder.]]></description>
										<content:encoded><![CDATA[<p>PM335 PRO is a panel-mounted meter designed with a form factor that fits 4-inch round or 92×92mm square cutouts. It monitors voltage, current, power, frequency, and energy measurements, while also providing power quality analysis and data logging capabilities.</p>
<p>PM335 PRO supports multiple communication protocols, including IEC 61850, DNP3, and IEC 60870-5-101/104, along with dual-port Ethernet connectivity. As a result, it serves as the ultimate solution for power monitoring, meeting and even exceeding the current requirements in utility, substation, industrial automation, and commercial energy management applications.</p>
<h5>Power Quality</h5>
<ul>
<li>Class A, Ed. 3.1 analyser per IEC 61000-4-30</li>
<li>EN50160 reports</li>
<li>Waveform capture and recording up to 256 samples/cycle</li>
<li>Up to 0.0001 Hz resolution</li>
<li>Leakage current detection via 4th current input</li>
<li>Individual harmonics, up to the 63rd harmonic</li>
<li><a class="link" title="Energy Network Association - Engineering Recommendation G99" href="https://www.energynetworks.org/assets/images/Files/ENA_EREC_G99_Issue_1_Amendment_9_(2022).pdf" target="_blank" rel="noopener">Compliance with ENA EREC G99</a></li>
</ul>
<p><a style="color: #272d4e; text-decoration: underline;" href="https://hitec-instruments.co.uk/dc-metering-dc-coupled-solar-pv-bess/" target="_blank" rel="noopener">DC metering</a> with <a style="color: #272d4e; text-decoration: underline;" href="https://hitec-instruments.co.uk/product/high-accuracy-dc-current-sensors/" target="_blank" rel="noopener">UHACS</a> or <a style="color: #272d4e; text-decoration: underline;" href="https://hitec-instruments.co.uk/product/hacs-high-accuracy-current-sensors/" target="_blank" rel="noopener">Hall Effect Sensors</a></p>
<ul>
<li>Up to 4000A DC with SATEC supplied sensors</li>
<li>Up to 820V DC direct measurement</li>
<li>Up to 1500V DC with supplied <a style="color: #272d4e; text-decoration: underline;" href="https://hitec-instruments.co.uk/product/voltage-ratio-module-dc-metering/" target="_blank" rel="noopener">Voltage Ratio Module</a></li>
</ul>
<h5>Revenue Meter</h5>
<ul>
<li>Class 0.2/0.2S accuracy; anti-tamper design; IR interface</li>
</ul>
<h5>Communication &amp; I/O</h5>
<ul>
<li>Dual Port Ethernet: RSTP support</li>
<li>IEC 61850</li>
<li>Open protocol: Modbus TCP/RTU, DNP3, IEC 60870-5-101/104</li>
<li>USB port (Type C)</li>
<li>Built-in I/O (optional): 1 RO; 2 DI; 1 AI</li>
<li>Modular I/O: up to 24 digital I/O</li>
</ul>