AQ-G257
Generator Protection Relay

Protection, synchronisation, event analysis
and power system integration for generator applications

Modern generator protection extends beyond fault detection and tripping.

On many projects, the same device must check synchronism, record disturbances and pass reliable data into the site’s control or substation automation system.

Protection, control, monitoring and communication are often engineered as parts of the same system rather than separate functions.

Generator Differential Protection • Synchroniser • Disturbance Recorder • IEC 61850 • Integrated AVR • Up to 9 Expansion Slots • Modular Hardware Platform

Generator Protection

Generator protection is designed to detect internal faults, abnormal operating conditions and electrical disturbances that can damage the generator, transformer or associated equipment.

AQ-G257 combines multiple protection functions within a single platform, allowing protection schemes to be adapted to different generator types and operating requirements.

Key protection and monitoring functions:

Fault Protection

  • Differential Protection
  • Restricted Earth Fault Protection
  • Stator Earth Fault Protection
  • Overcurrent Protection

Generator Condition Monitoring

  • Thermal Protection
  • Negative Sequence Protection
  • Underexcitation Protection

Voltage & Frequency Supervision

  • Overvoltage Protection
  • Undervoltage Protection
  • Overfrequency Protection
  • Underfrequency Protection
  • ROCOF Protection

Generator operation depends on more than fault protection alone.

Before a generator can be connected to the power system, synchronisation conditions must be verified. During operation, stability limits, excitation conditions, voltage and frequency behaviour may also require continuous supervision.

AQ-G257 combines synchronisation, stability supervision and system monitoring functions within the same platform, helping operators maintain reliable generator operation under both normal and disturbed network conditions.

Key synchronisation and stability functions:

Generator Synchronisation

• Synchroniser
• Synchrocheck
• Dead Bus Synchronisation

Generator Stability

• Underexcitation Protection
• Pole Slip Protection
• Power Factor Protection

System Frequency & Voltage Supervision

• ROCOF Protection
• Overfrequency Protection
• Underfrequency Protection
• Overvoltage Protection
• Undervoltage Protection
• Volts-per-Hertz (V/Hz) Protection

Pole Slip Protection
Loss of Synchronism Supervision

Underexcitation Protection
Generator stability supervision

Volts-per-Hertz (V/Hz) Protection
Overexcitation supervision

AQ-G257 provides event recording, disturbance analysis and operational monitoring functions that help engineers investigate system behaviour and analyse protection operations

Event Recording

  • Sequence of Events (SOE)
  • Time-Stamped Event Logs
  • Fault Records

Disturbance Analysis

  • Oscillography Records
  • COMTRADE Export
  • Pre-Fault and Post-Fault Data

Operational Visibility

  • Real-Time Measurements
  • Status Monitoring
  • Alarm Management

Disturbance Recording
Configurable analogue and digital disturbance recording

Waveform Analysis
Recorded signals can be reviewed in AQViewer

Event Timing
Cursors help compare signal timing during fault analysis

  • IEC 61850
  • COMTRADE
  • Disturbance Recorder integration
  • Automation systems
  • SCADA connectivity
  • Event data exchange

IEC 61850 Integration
communication for substation automation systems

SCADA Connectivity
Integration with SCADA systems via IEC 61850 and Modbus

GOOSE Subscription
Importing publisher SCL files

AQ-G257 can be adapted to additional monitoring, control and communication requirements without introducing separate devices for individual functions.

Additional I/O Capacity
• Expansion of digital inputs and outputs for plant-specific control and monitoring requirements
• High-speed output modules for applications requiring fast trip signalling
• Milliampere input and output modules for process integration

Generator Temperature Monitoring
• Up to 16 RTD inputs
• Thermal alarming and tripping based on temperature measurements

Additional Protection Functions
• Optional arc protection module
• External RTD and process signal expansion modules

Communication & System Integration
• Additional Ethernet and fibre-optic communication options
• IRIG-B time synchronisation
• HSR and PRP network redundancy
• Serial communication interfaces

RTD Input Module

RS-232 / Serial Fibre Communication
IIRIG-B Time Synchronisation
IArc Flash Detection
IIRIG-B Time Synchronisation

AQ-G257 Expansion Platform

Key Platform Specifications
Parameter AQ-G257
Current Inputs 10
Voltage Inputs 4
Standard Digital Inputs 3
Standard Digital Outputs 5
Expansion Slots 9
Event Recorder Capacity 15,000 records
Disturbance Records Capacity 100 records
Sampling Frequency 3.2 kHz
RTD Expansion Up to 8 inputs per module
Communication Protocols IEC 61850, IEC 60870-5-101, IEC 60870-5-103, DNP3, Modbus RTU/TCP, SPA
Power & Energy Accuracy 0.5%
Optional Power & Energy Accuracy 0.2%
Typical Applications
Utility Power Generation

Protection and synchronisation for utility-scale generating units and power stations.

Renewable Power Generation

Generator protection for renewable energy facilities, hybrid plants and grid-connected generation.

CHP Plants

Protection and control for combined heat and power generation systems.

Industrial Power Generation

Protection and control for industrial generation systems and on-site power plants.

Data Centres & Critical Infrastructure

Generator protection for standby generation and mission-critical power systems.

Grid Support Generation

Protection and synchronisation for grid support and reserve power generation.

Related Products

AQ-1000
Arc Quenching Device
(low-voltage)

AQ-F255
Feeder and Line Protection Relay

AQ-F215
Feeder Protection Relay

AQ-110PLV
Arc Flash Protection Relay